Un buon prezzo.  in linea

dettagli dei prodotti

Casa. > prodotti >
Test di penetrazione
>
Twin NiCr Sensitivity Panels NiCr Twin Cracked TypeⅠASTM E1417 AMS 2647D ISO 3452 JIS Z 2343-3

Twin NiCr Sensitivity Panels NiCr Twin Cracked TypeⅠASTM E1417 AMS 2647D ISO 3452 JIS Z 2343-3

Marchio: HUATEC
Numero di modello: TipoⅠ
MOQ: 1 pz
Dettagli dell'imballaggio: Pacchetto di esportazione standard
Termini di pagamento: T/T, PayPal, Western Union
Informazioni Dettagliate
Luogo di origine:
Pechino
Certificazione:
ISO, CE, GOST
Materiale:
NiCr
Colore:
Argento
Nome:
EsemplareⅠ di Typetest
Standard:
3452-3:1998 DI ISO (E), 2343-3:2001 DI JIS Z
Nome del prodotto:
Ispezione di liquido penetrante di tintura
Standard:
2343-3:2001 DI JIS Z
Capacità di alimentazione:
500 pezzi al mese
Evidenziare:

nicr penetrant testing

,

penetrant testing panels

Descrizione del prodotto

TypeⅠASTM E1417, AMS 2647D, ISO 3452-3, JIS Z 2343-3 Twin NiCr Sensitivity Panels NiCr Twin Cracked Penetrant Test Panels

 

TypeⅠPenetrate block :ISO 3452-3:1998(E),JIS Z 2343-3:2001

Twin NiCr Sensitivity Panels,NiCr Twin Cracked Penetrant Test Panels

ISO 3452-3 Type 1 Test Panel

 

The NiCr Twin Cracked Penetrant Test Panels are used for comparing and evaluating sensitivity and performance of Dye Penetrants.

They are available in 10, 20, 30 and 50 microns (0.0004, 0.0008, 0.0012, 0.002 inch) flaw depth.

Each set consists of a pair of identical panels marked A and B with manufacturer`s certification and crack photograph.

These panels are made by plating hard Nickel Chromium alloy on a 2mm thick brass substrate and stressing the panel in tension. The hard NiCr is brittle in comparison to the brass substrate so that the cracks created in the plated layer are limited to the thickness of the layer. The panel is then cut in half perpendicular to the direction of the cracks thus creating a matching pair of virtually identical cracks of controlled depth.

NiCr Panels are used to compare new and used penetrants and can also be used for comparing performance of different penetrant materials or different processing techniques.

Sensitivity* (unofficial) Fluorescent Penetrant Sensitivity Levels are established by the USAF Laboratory under highly controlled conditions. Sensitivity testing is not something the penetrant manufacturer or user can do. What you can do is compare samples using appropriate NiCr Cracked Panels.

 

 

Crack Depth

 

Level

50 μm 1, 2, 3, 4
30 μm 2, 3, 4
20 μm 3, 4
10 μm 4


Guaranteed to be equivalent to both Sherwin and Magnaflux supplied panels.

Specifications Compliance: ASTM E1417, AMS 2647D, ISO 3452-3, JIS Z 2343-3

 

 

Standard delivery:

YM-B block 1 set

Calibration certificate 1 pc

Case 1 pc 

Valutazioni e revisione

Valutazione complessiva

5.0
Sulla base di 50 recensioni per questo fornitore

Rappresentazione del rating

Di seguito è riportata la distribuzione di tutte le valutazioni
5 Stelle
100%
4 Stelle
0%
3 Stelle
0%
2 Stelle
0%
1 Stelle
0%

Tutte le recensioni

1
12
Brazil Oct 29.2025
123